Vlc 1600 Datasheet |best|

The VLC-1600 functions cleanly within open-protocol industrial frameworks. It is fully certified by the BACnet Testing Laboratories (BTL) as an Application Specific Controller.

Senses binary states (On/Off, Closed/Open) for status tracking, filter monitors, and alarms.

Alerton VLC-1600 VisualLogic Unitary Field Controller, Input Monitoring Device [New] | B2E Surplus ₹87,019.92($916.07) Go to product viewer dialog for this item.

: If an exact, legacy matching assembly is required for certified subpanels, industrial hardware pools like Radwell International keep verified stock of original VLC-1600 control system boards.

: Non-volatile flash memory for program and data storage, ensuring reliability during power cycles. Internal Speed : Logical loop time of for high-speed data processing.

The VLC 1600 can emit 1.6 W of continuous optical power but requires a drive current up to 2.4 A. Thermal management is critical. vlc 1600 datasheet

The VLC-1600 is a native BACnet controller, designed for seamless integration into building automation systems: : Communicates on a BACnet MS/TP LAN at speeds up to 115.2 Kbps (depending on the model). Smart Sensors : Supports intelligent wall sensors including the Microset, Microset II, and Microset 4 on Input 0. Programming : Fully programmable using Alerton’s VisualLogic graphical toolset. Physical and Environmental Attributes Dimensions : 4.90” H x 5.45” W x 1.40” D (125mm x 138mm x 36mm). Operating Limits

[BACnet MS/TP Trunk] <---> EIA-485 Physical Layer <---> [VLC-1600 Terminal Blocks] | (Internal Logic Loop: 100ms) | [16-Bit Universal Inputs] Communication Protocol Specifications

model features hardware-based . It synchronizes automatically with the local trunk speed at 9.6, 19.2, 38.4, 76.8, or 115.2 Kbps. An integrated, onboard network status LED displays packet transmissions to simplify physical network troubleshooting. Physical Installation and Environmental Frameworks

Since “VLC 1600” is obscure, try these steps:

Vishay Dale Category: Inductors, Coils, Chokes Status: Active / In Production Internal Speed : Logical loop time of for

This article provides a deep dive into the , highlighting its technical specifications, key features, and typical applications. 1. Overview of the VLC-1600 Controller

The primary design objective of the VLC-1600 series is to expand telemetry dense zones without forcing operators to purchase redundant output circuits. Unlike generic unitary field controllers that split allocations between inputs and outputs (such as the VLC-16160), the VLC-1600 focuses entirely on high-resolution data acquisition. The series exists in two main hardware generations:

| Feature | VLC-1600 (Standard) | VLC-1600-E (Advanced) | | :--- | :--- | :--- | | | Not specified in mainstream catalogs | ARM Cortex-M4F, 32-bit @ 80 MHz | | Number of Inputs | 16 Universal Inputs (UI) | 16 Universal Inputs (UI) | | Input Resolution | 10-bit resolution | 16-bit high resolution | | Input Types (Universal) | Thermistor/NTC; Dry Contact; Pulse; 0-5 VDC; 0-10 VDC; 4-20 mA | Thermistor; Dry Contact; Pulse; 0-5 V; 0-10 V; 4-20 mA (auto-selectable) | | Outputs | None (purely input monitoring) | None (purely input monitoring) | | Supported Sensors | Alerton BACtalk® Microset, Microset II, Microset 4 | Alerton BACtalk® Microset, Microset II, Microset 4 | | Communication Speed | Up to 76.8 Kbps on MS/TP network | Up to 115.2 Kbps on MS/TP network (BACnet MS/TP) | | Memory | Non-volatile flash memory for program/parameter backup | 512 MB of non-volatile flash memory | | Power Supply | 24 VAC | 24 VAC | | Physical Dimensions (W x H x D) | Not specified | 125 × 127 × 36 mm (4.92 × 5.00 × 1.42 in) | | Weight | ~4.54 kg (for VLC-1600C3 variant) | ~0.3 kg (for VLC-1600-E) |

Never place 24 VAC supply wires or RS-485 communication paths inside the same conduit or enclosure as high-voltage lines.

This article provides a detailed breakdown of the , including technical specifications, features, applications, and installation details. 1. Product Overview: The Alerton VLC-1600 automatically synchronizing data speeds across 9.6kbps

When using 4–20 mA loops or current sensing signals, ensure the shield drains connect cleanly to earth ground at a single point to prevent ground loops. Legacy Compatibility & Ordering Profiles

The advanced capabilities of the VLC-1600-E, in particular, make it a versatile tool for modern building intelligence. Its high-resolution 16-bit universal inputs and powerful 32-bit ARM Cortex-M4F processor at 80 MHz provide the horsepower needed for precise data handling and complex algorithmic analysis. The device's 512 MB of flash memory allows for substantial on-board logic storage, while non-volatile memory ensures that all programmed settings are preserved even during a power loss, guaranteeing stable and reliable operation. The unit is programmed using Alerton's VisualLogic, an intuitive, graphical, drag-and-drop programming language that simplifies the creation of custom monitoring sequences without requiring extensive coding expertise. The supported sensor ecosystem is a key advantage; the VLC-1600 works with the full range of Alerton BACtalk® sensors, including the popular Microset, Microset II, and Microset 4 intelligent wall sensors, which provide convenient local data display, setpoint adjustment, and technician access for equipment setup parameters. Furthermore, its BTL (BACnet Testing Laboratories) certification guarantees that it will communicate flawlessly with products from other BACnet-compliant manufacturers, preventing vendor lock-in and ensuring a truly open and interoperable building management system.

Supports intelligent wall sensors (Microset series) for convenient display of data and setpoint adjustment. 4. Typical Applications

: The modern -E variant employs integrated auto-baud switching, automatically synchronizing data speeds across 9.6kbps, 19.2kbps, 38.4kbps, 76.8kbps, or 115.2kbps network segments.