Sokkia Prolink 115 Software Free Download Install |best| Jun 2026

Since Prolink 1.15 is considered "legacy" software, it is no longer actively marketed on the official Sokkia website. However, you can still find it through several reliable channels:

If successful, the status bar in ProLink will show “Connected” and the instrument model.

Under the Settings section, check the box for . Click Apply and then OK . Step 3: Running the Installation Wizard

The communication settings in Prolink must identically match the internal settings configured on your Sokkia total station. Common standard settings include: 9600 or 1200 Data Bits: 8 Parity: None Stop Bits: 1 Modern and Safe Alternatives to Prolink

: Open the downloaded file to launch the install wizard; you may need to grant administrative permissions. sokkia prolink 115 software free download install

Allows basic manual editing of point numbers, codes, and descriptions before office exporting. The Reality of "Free Download" Links

If you are looking for the process, this article provides a comprehensive guide to acquiring, installing, and utilizing this software effectively. What is Sokkia ProLink 1.15?

Prolink 1.15 cannot recognize the cable if the driver is broken or missing.

Many regional Sokkia dealers host the installer on their support pages. Examples: Since Prolink 1

Download the installation files from an authorized Sokkia distributor or trusted surveying archive. Extract the downloaded ZIP folder to your desktop. Step 2: Configure Windows Compatibility Open the extracted folder and locate Setup.exe . Right-click Setup.exe and select . Navigate to the Compatibility tab.

Sokkia Prolink was originally distributed as proprietary software alongside Sokkia surveying instruments. Over time, Sokkia discontinued development and support for the Prolink series, transitioning users to Sokkia Link and later to GeoMax or Topcon Magnet office suites. Is there an official free download?

: The software is no longer hosted on official Sokkia or Topcon positioning websites.

ProLink 115 is specifically designed for older RS-232C serial communication, though it can also work over USB-to-serial adapters. Version 1.15 (hence the name) was one of the last stable releases before Sokkia began integrating with broader software suites. Click Apply and then OK

Once you have the installer, follow these steps to get ProLink running on your Windows machine: Sokkia Prolink Version 1.15 Download - Facebook

| Problem | Possible Cause | Solution | |--------|----------------|------------| | “Port not found” | COM port > 9 | Reassign COM port in Device Manager to COM1–COM4 | | “Timeout error” | Baud rate mismatch | Match baud rate on PC and total station (try 4800 or 19200) | | Garbled text | Parity or stop bits incorrect | Set Parity=None, Stop Bits=1 | | Installer won’t run | 64-bit security block | Run as Administrator + disable SmartScreen temporarily | | Can’t download file | Dead link | Use Internet Archive’s Wayback Machine (search for sokkia.com/support/downloads from 2010) |

The most common point of failure when utilizing Sokkia Prolink 1.15 today is the physical connection between the computer and the total station.

Do you already have the and its drivers?

If you are using relatively modern Sokkia equipment (iX, FX, or recent CX series), you should look for or Topcon MAGNET for a smoother experience. However, for those stuck with a dead COM port issue or a 90s-era SDR33, ProLink 1.15 is still the go-to solution.