Short press the UP button while on the main screen to toggle between voltage and percentage (calculated as: Battery Voltage / (UP - dn) ).
Here are the most frequently reported issues and their solutions. xycd60 manual
Follow these steps to resolve the most common issues: Short press the UP button while on the
Long press the SET button to enter the parameter setting interface. : In a solar system, you have solar
: In a solar system, you have solar panels (the charger) and a battery. Set "UP" to your battery's maximum voltage (e.g., 14.4V for a 12V lead-acid). Set "dn" to the voltage at which you want charging to begin again (e.g., 12.0V). When the battery voltage drops to 12.0V or below, the module connects the solar panel to charge it. Once it reaches 14.4V, it disconnects the panel, preventing overcharging.
The XY-CD60 is a multi-functional battery controller designed to automate the charging and discharging cycles of DC batteries. Supporting a wide voltage range (6V to 60V), it acts as a safeguard against overcharging and deep discharging, which are critical factors in extending battery lifespan. 2. Technical Specifications Voltage Range: DC 6V–60V. Control Accuracy: Output Type: Direct output (Relay switch). Voltage Error: plus or minus 0.1 cap V Primary Modes: Charging Control (P-1): Activates when battery voltage drops below a lower limit. Discharging Control (P-2): Activates when battery voltage exceeds an upper limit. 3. Operating Modes and Logic
Set (Upper Limit): The voltage at which the load turns ON.